Factory Default Local Reset
To perform a local device reset, lightly press and hold the push button on the SZWAQ Insert for approximately 20 seconds until the LED turns SOLID RED, and then release.
- After 10 seconds the LED will illuminate SOLID BLUE; indicating user is passing through network add/remove period.
- After 15 seconds elapsed hold time, the LED will turn off
- After 20 seconds elapsed hold time, the LED will turn SOLID RED; indicating that the user has entered the device reset period. Releasing the button during this period triggers the Factory Default Local Reset operations.
When the Reset operation is in progress, the LED will progress from red to green to blue repeatedly until the reset process is complete, after which the LED will return to its default state.
If the user continues to hold the button, after 25 seconds elapse, the user will leave the device reset period, no actions will be taken when the button is released, and the LED will return to its default state.
NOTE: The local reset procedure should only be used when the original controller is inoperable or has been replaced, or if Network Add or Network Remove operations have failed after a few attempts.
Resetting to factory default settings will reset the SZWAQ Insert network parameters to the default removed state, reset configuration parameters to their factory default states, and delete all association group entries.