For additional parameters and to learn more, please download our Swidget Z-Wave Universal Insert Configuration guide.
Humidity High Entry Level
Parameter: 128 (0x0080)
Description: Used to set the humidity value that indicates entry into a high/over humidity state.
Range: 0 to 100
Units: Percent
Default: 100
Humidity Low Entry Level
Parameter: 129 (0x0081)
Description: Used to set the humidity value that indicates entry into a low/under humidity state.
Range: 0 to 100
Units: Percent
Default: 0
Humidity High Exit Level
Parameter: 130 (0x0082)
Description: Used to set the humidity value that indicates exit from a high/over humidity state.
Range: 0 to 100
Units: Percent
Default: 100
Humidity Low Exit Level
Parameter: 131 (0x0083)
Description: Used to set the humidity value that indicates exit from a low/under humidity state.
Range: 0 to 100
Units: Percent
Default: 0
Humidity High Delay
Parameter: 132 (0x0084)
Description: Used to set the time duration for high/over humidity state changes.
Range: 0 – 65535
Units: Seconds
Default: 0
Humidity High Entry SET Value
Parameter: 137 (0x0089)
Description: BASIC SET value sent to associated nodes on entry into high/over-humidity state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 255 (turn on associated devices)
Humidity High Exit SET Value
Parameter: 138 (0x008A)
Description: BASIC SET value sent to associated nodes on exit from high/over-humidity state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 0 (turn off associated devices)
Humidity Low Entry SET Value
Parameter: 139 (0x008B)
Description: BASIC SET value sent to associated nodes on entry into low/under humidity state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 255 (turn on associated devices)
Humidity Low Exit SET Value
Parameter: 140 (0x008C)
Description: BASIC SET value sent to associated nodes on exit from low/under humidity state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 0 (turn off associated devices)