For additional parameters and to learn more, please download our Swidget Z-Wave Universal Insert Configuration guide.
Temperature High Entry Level
Parameter: 80 (0x0050)
Description: Used to set the temperature value that indicates entry into a high/over temperature state.
Range: -400 to +850 (tenths of a degree Celsius), -400 to +1850 (tenths of a degree Fahrenheit)
Units: Tenths of a Degree (*0.1)
Default: +230 (23.0° Celsius), +734 (73.4° Fahrenheit)
Temperature Low Entry Level
Parameter: 81 (0x0051)
Description: Used to set the temperature value that indicates entry into a low/under temperature state.
Range: -400 to +850 (tenths of a degree Celsius), -400 to +1850 (tenths of a degree Fahrenheit)
Units: Tenths of a Degree (*0.1)
Default: +170 (17.0° Celsius), +626 (62.6° Fahrenheit)
Temperature High Exit Level
Parameter: 82 (0x0052)
Description: Used to set the temperature value that indicates exit from a high/over temperature state.
Range: -400 to +850 (tenths of a degree Celsius), -400 to +1850 (tenths of a degree Fahrenheit)
Units: Tenths of a Degree (*0.1)
Default: +230 (23.0° Celsius), +734 (73.4° Fahrenheit)
Temperature Low Exit Level
Parameter: 83 (0x0053)
Description: Used to set the temperature value that indicates exit from a low/under temperature state.
Range: -400 to +850 (tenths of a degree Celsius), -400 to +1850 (tenths of a degree Fahrenheit)
Units: Tenths of a Degree (*0.1)
Default: +170 (17.0° Celsius), +626 (62.6° Fahrenheit)
Temperature Periodic Report
Parameter: 86 (0x0056)
Description: Used to set the time in seconds between sending a periodic MULTILEVEL SENSOR REPORT to the Lifeline.
Range: 0 to 65535 seconds
Units: Seconds
Default: 3600 (1 hour)
Temperature Change Report
Parameter: 87 (0x0057)
Description: Used to set the temperature in degrees that a reported reading must change by to trigger a new temperature MULTILEVEL SENSOR REPORT to the Lifeline.
Range: 0 – 255
Units: Tenths of a Degree Celsius or Fahrenheit (*0.1)
Default: 10 (1.0°)
Temperature High Entry SET Value
Parameter: 89 (0x0059)
Description: BASIC SET value sent to associated nodes on entry into high/over-temperature state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 255 (turn on associated devices)
Temperature High Exit SET Value
Parameter: 90 (0x005A)
Description: BASIC SET value sent to associated nodes on exit from high/over-temperature state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 0 (turn off associated devices)
Temperature Low Entry SET Value
Parameter: 91 (0x005B)
Description: BASIC SET value sent to associated nodes on entry into low/under temperature state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 255 (turn on associated devices)
Temperature Low Exit SET Value
Parameter: 92 (0x005C)
Description: BASIC SET value sent to associated nodes on exit from low/under temperature state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 0 (turn off associated devices)
Temperature Units
Parameter: 95 (0x005F)
Description: Used to set the temperature unit of measurement.
Values: 0x00: Celsius, 0x01: Fahrenheit
Units: N/A
Default: 0 (Celsius)