How Swidget Z-Wave 800-series inserts appear to Z-Wave hubs, and how to configure, move and update them.
Firmware tags: FW 2.0 firmware 2.0 FW 1.8 firmware 1.8. A tag in front of a line means only that firmware has it; text without a tag applies to both. Firmware 1.7 and older is not covered here: update to 1.8 first.
Which firmware do I have? In Home Assistant, open the insert under Settings, Devices & services, Z-Wave, Devices: the Device info card shows the firmware version. To update, see Updating a Swidget Z-Wave insert to firmware 2.0.
The products
All four inserts share the same Z-Wave 800 control board, with a different daughterboard fitted at the factory. One firmware serves all of them: at power-up the insert works out which daughterboard it has and which Swidget host it is plugged into.
| Model | Name | Adds |
|---|---|---|
| ZW000UWA | Z-Wave Universal Control | control and power metering of the host |
| ZW001UWA | Z-Wave Control + USB | a switchable USB-A charging port (its own endpoint) |
| ZW006UWA | Z-Wave Control + Temperature/Humidity/Motion | temperature, humidity and motion |
| ZW008UWA | Z-Wave Control + Air Quality | air quality (VOC index), temperature and humidity |
- The Air Quality insert does not report barometric pressure.
- Each insert has its own Z-Wave identity: the DSK and QR code on its label.
- This page covers the 800-series inserts. Earlier ("original") Swidget Z-Wave inserts are different hardware and don't receive firmware updates.
Hosts
An insert always sits in a Swidget host. The host decides what the insert controls and measures.
| Host | Type byte | Load control | Power metering |
|---|---|---|---|
| 15 A outlet (R1015SWA) | 0x01 | top receptacle switched | both receptacles (2 meters) |
| 20 A outlet (R1020SWA) | 0x02 | top receptacle switched | both receptacles (2 meters) |
| On/off switch, 3-way capable | 0x03 | on/off | yes |
| Dimmer | 0x04 | dimming | yes |
| Multi-way dimmer | 0x05 | dimming | yes |
| Auxiliary / relay switch (S16009WA) | 0x06 | on/off | no |
| 20/40/60 timer switch (S16008WA) | 0x07 | on/off with timer | no |
How it identifies itself
Values in the Manufacturer Specific Report, which hubs use to pick a driver:
| Field | Value |
|---|---|
| Manufacturer ID |
0x0345 (Swidget Corp) |
| Product Type ID | high byte = host (table above); low byte = daughterboard: 0x00 control only, 0x01 USB, 0x05 Air Quality, 0x08 Temperature/Humidity/Motion |
| Product ID |
0x0002 (Z-Wave 800 Universal Insert) |
| Firmware ID |
0x0401, the same for every model |
So a Temperature/Humidity/Motion insert in a timer switch reports Product Type 0x0708, and SmartThings shows the manufacturer as 0345.
The Temperature/Humidity/Motion low byte is 0x08. Some copies of its Technical Notes give 0x06, which is a misprint.
The identity stays the same while the insert stays in the same host and on the same network, so hub drivers see a stable fingerprint.
Z-Wave features
- Z-Wave Plus v2, always on (mains powered), and a repeater for the mesh.
- Security: S2 Unauthenticated, S2 Authenticated and S0. SmartStart inclusion from the QR code, or classic inclusion with the button.
- FW 2.0 Z-Wave Long Range (US and Canada). The hub chooses classic Z-Wave or Long Range when it includes the insert by SmartStart, and offers Long Range only when the QR code lists it. Labels on inserts sold with 1.x firmware don't, so those inserts join on standard mesh unless you scan a Long Range version of the code, made from the label on the Swidget Long Range QR code page. On Long Range only the Lifeline association works, only S2 is used, and the parameter options that send Basic Sets to association groups are hidden.
- Command classes: Basic; Binary Switch (on/off hosts and the USB port); Multilevel Switch (dimmers); Meter (hosts with metering); Multilevel Sensor and Notification (sensor inserts); Configuration; Association, Multi Channel Association, Association Group Information; Multi Channel (outlets and the USB insert); Indicator (Identify); Firmware Update; Version; Manufacturer Specific; Device Reset Locally; Powerlevel; Supervision; Transport Service; Security 0 and 2; Z-Wave Plus Info.
- Endpoints: outlets have two (top, bottom); the USB insert adds one for the USB port; other hosts have none.
The button
Hold the button, watch the LED, and release when it shows the action you want.
| Hold, then release | LED while held | Does |
|---|---|---|
| under 1 s | no change | nothing |
| 1 to 5 s | green | toggles the host's load |
| 5 to 10 s | blue | network add / remove (inclusion / exclusion) |
| 10 to 15 s | red | factory reset |
| over 15 s | off | nothing |
After a factory reset the insert takes several seconds before it restarts. A factory reset tells the hub the insert has left the network.
Some older instructions say to hold for about 20 seconds until solid red. That is wrong for every Swidget Z-Wave insert: red (factory reset) is 10 to 15 seconds, as above.
Association groups
Group 1 is the Lifeline, which reports to the hub. The other groups are numbered consecutively in this order, and only those that apply to the host and daughterboard are present:
- Lifeline (always group 1)
- Switch (always group 2)
- High Power 1, Low Power 1 (hosts with metering)
- High Power 2, Low Power 2 (outlets: the bottom receptacle)
- Motion (Temperature/Humidity/Motion)
- Air Quality (Air Quality)
- High Temperature, Low Temperature, High Humidity, Low Humidity (Temperature/Humidity/Motion, Air Quality)
There are no gaps, so the same group has a different number on different hosts:
| Insert in... | Groups |
|---|---|
| ZW006UWA in an aux or timer switch | 1 Lifeline, 2 Switch, 3 Motion, 4 High Temp, 5 Low Temp, 6 High Humidity, 7 Low Humidity |
| ZW006UWA in an on/off switch or dimmer | 1 Lifeline, 2 Switch, 3 High Power 1, 4 Low Power 1, 5 Motion, 6 High Temp, 7 Low Temp, 8 High Humidity, 9 Low Humidity |
| ZW006UWA in an outlet | 1 Lifeline, 2 Switch, 3 to 6 High/Low Power 1 and 2, 7 Motion, 8 High Temp, 9 Low Temp, 10 High Humidity, 11 Low Humidity |
| ZW008UWA in an outlet | 1 Lifeline, 2 Switch, 3 to 6 High/Low Power 1 and 2, 7 Air Quality, 8 High Temp, 9 Low Temp, 10 High Humidity, 11 Low Humidity |
| ZW000UWA / ZW001UWA in an outlet | 1 Lifeline, 2 Switch, 3 to 6 High/Low Power 1 and 2 |
Hubs read the group names from Association Group Information, so a hub that shows names is the safest guide.
Configuration parameters
Only the parameters that apply to your host and insert appear on your hub. Each group below says which hosts and inserts it applies to.
Reading the tables
- Times are in seconds. A periodic report or renotification of 1 to 29 seconds is treated as 30; 0 turns it off.
- Entry and exit levels form a band: the insert enters the HIGH (or LOW) state at the entry level and leaves it at the exit level, so it doesn't flap around one value.
- SET values are what the insert sends in a Basic Set (or sets its own load to): 0 to 99 is a level, 255 is "on".
- Actions parameters are bit fields: add up the values of the options you want (listed under each one).
- A parameter tagged FW 2.0 is offered to hubs only on firmware 2.0.
- 155, Host Change Operation: set it to 2 if an insert resets itself after a power outage; the insert then only flashes its LED when it sees a different host.
Power monitoring: controlled load
Applies to: 15 A outlet, 20 A outlet, On/off switch, Dimmer, Multi-way dimmer; any insert.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 1 |
Power 1 High Entry Level Power 1 level that enters the HIGH state (W). |
2400 | 0 to 2400 | 2 |
| 2 |
Power 1 Low Entry Level Power 1 level that enters the LOW state (W). |
0 | 0 to 2400 | 2 |
| 3 |
Power 1 High Exit Level Power 1 level that leaves the HIGH state (W). |
2400 | 0 to 2400 | 2 |
| 4 |
Power 1 Low Exit Level Power 1 level that leaves the LOW state (W). |
0 | 0 to 2400 | 2 |
| 5 |
Power 1 High Delay Time the HIGH condition must hold before acting (s). |
0 | 0 to 65535 | 2 |
| 6 |
Power 1 Low Delay Time the LOW condition must hold before acting (s). |
0 | 0 to 65535 | 2 |
| 7 |
Power 1 Periodic Report Periodic meter report interval (s); 0 = off, 1 to 29 are treated as 30. |
3600 | 0 to 65535 | 2 |
| 8 |
Power 1 Change Report Report when power changes by this much (W); 0 = off. |
5 | 0 to 2400 | 2 |
| 9 |
Power 1 Renotification Delay Repeat interval while HIGH/LOW persists (s); 0 = off, 1 to 29 are treated as 30. |
0 | 0 to 65535 | 2 |
| 10 |
Power 1 High Entry SET Value Value sent (Basic Set) on HIGH entry; 0 to 99 or 255 (on), 100 to 254 are treated as 99. |
255 | 0 to 255 | 1 |
| 11 |
Power 1 High Exit SET Value Value sent on HIGH exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 12 |
Power 1 Low Entry SET Value Value sent on LOW entry; 0 to 99 or 255 (on). |
255 | 0 to 255 | 1 |
| 13 |
Power 1 Low Exit SET Value Value sent on LOW exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 14 |
Power 1 High Actions HIGH-state actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Send a meter report on entry and exit 32 = Apply the entry delay 64 = Apply the exit delay |
99 | 0 to 127 | 2 |
| 15 |
Power 1 Low Actions LOW-state actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Send a meter report on entry and exit 32 = Apply the entry delay 64 = Apply the exit delay |
99 | 0 to 127 | 2 |
| 16 |
Power 1 System Configuration Periodic report content. 1 = Periodic power (W) reports 2 = Periodic energy (kWh) reports |
2 | 0 to 3 | 2 |
Power monitoring: bottom receptacle
Applies to: 15 A outlet, 20 A outlet; any insert.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 24 |
Power 2 High Entry Level Power 2 level that enters the HIGH state (W). |
2400 | 0 to 2400 | 2 |
| 25 |
Power 2 Low Entry Level Power 2 level that enters the LOW state (W). |
0 | 0 to 2400 | 2 |
| 26 |
Power 2 High Exit Level Power 2 level that leaves the HIGH state (W). |
2400 | 0 to 2400 | 2 |
| 27 |
Power 2 Low Exit Level Power 2 level that leaves the LOW state (W). |
0 | 0 to 2400 | 2 |
| 28 |
Power 2 High Delay Time the HIGH condition must hold before acting (s). |
0 | 0 to 65535 | 2 |
| 29 |
Power 2 Low Delay Time the LOW condition must hold before acting (s). |
0 | 0 to 65535 | 2 |
| 30 |
Power 2 Periodic Report Periodic meter report interval (s); 0 = off, 1 to 29 are treated as 30. |
3600 | 0 to 65535 | 2 |
| 31 |
Power 2 Change Report Report when power changes by this much (W); 0 = off. |
5 | 0 to 2400 | 2 |
| 32 |
FW 2.0 Power 2 Renotification Delay Repeat interval while HIGH/LOW persists (s); 0 = off, 1 to 29 are treated as 30. |
0 | 0 to 65535 | 2 |
| 33 |
Power 2 High Entry SET Value Value sent (Basic Set) on HIGH entry; 0 to 99 or 255 (on), 100 to 254 are treated as 99. |
255 | 0 to 255 | 1 |
| 34 |
Power 2 High Exit SET Value Value sent on HIGH exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 35 |
Power 2 Low Entry SET Value Value sent on LOW entry; 0 to 99 or 255 (on). |
255 | 0 to 255 | 1 |
| 36 |
Power 2 Low Exit SET Value Value sent on LOW exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 37 |
Power 2 High Actions HIGH-state actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Send a meter report on entry and exit 32 = Apply the entry delay 64 = Apply the exit delay |
99 | 0 to 127 | 2 |
| 38 |
Power 2 Low Actions LOW-state actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Send a meter report on entry and exit 32 = Apply the entry delay 64 = Apply the exit delay |
99 | 0 to 127 | 2 |
| 39 |
Power 2 System Configuration Periodic report content. 1 = Periodic power (W) reports 2 = Periodic energy (kWh) reports |
2 | 0 to 3 | 2 |
Motion
Applies to: any host; ZW006UWA.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 48 |
Motion Sensitivity Level Motion needed before the insert reports occupied. 0 = triggers on the first detection (most sensitive); 1 to 100: higher values need motion to last longer. |
0 | 0 to 100 | 1 |
| 49 |
Motion Renotification Delay Repeat interval for the occupied notification (s); 0 = off, 1 to 29 are treated as 30. |
300 | 0 to 65535 | 2 |
| 50 |
Motion Reset Delay Time without motion before occupancy clears (s). |
300 | 0 to 65535 | 2 |
| 51 |
Motion Detected Entry SET Value Value sent on motion detected; 0 to 99 or 255 (on). |
255 | 0 to 255 | 1 |
| 52 |
Motion Detected Exit SET Value Value sent when motion clears; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 53 |
Motion Actions Motion actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Repeat the occupied notification (uses the renotification delay) |
31 | 0 to 31 | 2 |
Air quality
Applies to: any host; ZW008UWA.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 64 |
FW 2.0 Air Quality Level 1 Index IAQ index at/above which air is level 1. |
100 | 0 to 500 | 2 |
| 65 |
Air Quality Level 2 Index IAQ index at/above which air is level 2. |
175 | 0 to 500 | 2 |
| 66 |
Air Quality Level 3 Index IAQ index at/above which air is level 3 (highest). |
250 | 0 to 500 | 2 |
| 67 |
Air Quality Alert Level Which level (1 to 3) raises the air quality alert. |
2 | 1 to 3 | 1 |
| 68 |
Air Quality Alert Delay Time the alert condition must hold (s). |
0 | 0 to 65535 | 2 |
| 69 |
Air Quality Renotification Delay Repeat interval for the alert (s); 0 = off, 1 to 29 are treated as 30. |
300 | 0 to 65535 | 2 |
| 70 |
Air Quality VOC Periodic Report Periodic VOC sensor report interval (s); 0 = off, 1 to 29 are treated as 30. |
3600 | 0 to 65535 | 2 |
| 72 |
Air Quality Alert Entry SET Value Value sent on alert entry; 0 to 99 or 255 (on). |
255 | 0 to 255 | 1 |
| 73 |
Air Quality Alert Exit SET Value Value sent on alert exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 74 |
Air Quality Actions Air-quality actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Repeat the alert notification (uses the renotification delay) |
19 | 0 to 31 | 2 |
Temperature
Applies to: any host; ZW006UWA, ZW008UWA.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 80 |
Temperature High Entry Level Temperature level that enters the HIGH state (0.1° in the selected unit; −40.0 to 85.0 °C). |
230 | -400 to 850 | 2 |
| 81 |
Temperature Low Entry Level Temperature level that enters the LOW state (0.1° in the selected unit; −40.0 to 85.0 °C). |
170 | -400 to 850 | 2 |
| 82 |
Temperature High Exit Level Temperature level that leaves the HIGH state (0.1° in the selected unit; −40.0 to 85.0 °C). |
230 | -400 to 850 | 2 |
| 83 |
Temperature Low Exit Level Temperature level that leaves the LOW state (0.1° in the selected unit; −40.0 to 85.0 °C). |
170 | -400 to 850 | 2 |
| 84 |
Temperature High Delay Time the HIGH condition must hold before acting (s). |
0 | 0 to 65535 | 2 |
| 85 |
Temperature Low Delay Time the LOW condition must hold before acting (s). |
0 | 0 to 65535 | 2 |
| 86 |
Temperature Periodic Report Periodic temperature report interval (s); 0 = off, 1 to 29 are treated as 30. |
3600 | 0 to 65535 | 2 |
| 87 |
Temperature Change Report Report when temperature changes by this much (0.1°); 0 = off. |
10 | 0 to 255 | 1 |
| 88 |
Temperature Renotification Delay Repeat interval while HIGH/LOW persists (s); 0 = off, 1 to 29 are treated as 30. |
0 | 0 to 65535 | 2 |
| 89 |
Temperature High Entry SET Value Value sent on HIGH entry; 0 to 99 or 255 (on). |
255 | 0 to 255 | 1 |
| 90 |
Temperature High Exit SET Value Value sent on HIGH exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 91 |
Temperature Low Entry SET Value Value sent on LOW entry; 0 to 99 or 255 (on). |
255 | 0 to 255 | 1 |
| 92 |
Temperature Low Exit SET Value Value sent on LOW exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 93 |
Temperature High Actions HIGH-temperature actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Send a temperature report on entry and exit 32 = Repeat the notification while the condition lasts 64 = Apply the entry delay 128 = Apply the exit delay |
227 | 0 to 255 | 2 |
| 94 |
Temperature Low Actions LOW-temperature actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Send a temperature report on entry and exit 32 = Repeat the notification while the condition lasts 64 = Apply the entry delay 128 = Apply the exit delay |
227 | 0 to 255 | 2 |
| 95 |
Temperature Units Unit for temperature reports and thresholds: 0 = °C, 1 = °F. |
0 | 0 to 1 | 1 |
| 96 |
FW 2.0 Temperature Offset Calibration offset added to the reading, in 0.1° of the selected unit. |
0 | -400 to 1850 | 2 |
Humidity
Applies to: any host; ZW006UWA, ZW008UWA.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 128 |
FW 2.0 Humidity High Entry Level Humidity level that enters the HIGH state (%RH). |
100 | 0 to 100 | 1 |
| 129 |
Humidity Low Entry Level Humidity level that enters the LOW state (%RH). |
0 | 0 to 100 | 1 |
| 130 |
Humidity High Exit Level Humidity level that leaves the HIGH state (%RH). |
100 | 0 to 100 | 1 |
| 131 |
Humidity Low Exit Level Humidity level that leaves the LOW state (%RH). |
0 | 0 to 100 | 1 |
| 132 |
Humidity High Delay Time the HIGH condition must hold before acting (s). |
0 | 0 to 65535 | 2 |
| 133 |
Humidity Low Delay Time the LOW condition must hold before acting (s). |
0 | 0 to 65535 | 2 |
| 134 |
Humidity Periodic Report Periodic humidity report interval (s); 0 = off, 1 to 29 are treated as 30. |
3600 | 0 to 65535 | 2 |
| 135 |
Humidity Change Report Report when humidity changes by this much (%RH); 0 = off. |
10 | 0 to 100 | 1 |
| 136 |
Humidity Renotification Delay Repeat interval while HIGH/LOW persists (s); 0 = off, 1 to 29 are treated as 30. |
0 | 0 to 65535 | 2 |
| 137 |
Humidity High Entry SET Value Value sent on HIGH entry; 0 to 99 or 255 (on). |
255 | 0 to 255 | 1 |
| 138 |
Humidity High Exit SET Value Value sent on HIGH exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 139 |
Humidity Low Entry SET Value Value sent on LOW entry; 0 to 99 or 255 (on). |
255 | 0 to 255 | 1 |
| 140 |
Humidity Low Exit SET Value Value sent on LOW exit; 0 to 99 or 255 (on). |
0 | 0 to 255 | 1 |
| 142 |
Humidity High Actions HIGH-humidity actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Send a humidity report on entry and exit 32 = Apply the entry delay 64 = Apply the exit delay 128 = Reserved (no effect) |
3 | 0 to 255 | 2 |
| 143 |
Humidity Low Actions LOW-humidity actions. 1 = Basic Set to the association group on entry 2 = Basic Set to the association group on exit 4 = Set this insert's own load on entry 8 = Set this insert's own load on exit 16 = Send a humidity report on entry and exit 32 = Apply the entry delay 64 = Apply the exit delay 128 = Reserved (no effect) |
3 | 0 to 255 | 2 |
| 144 |
Humidity Offset Calibration offset added to the reading (%RH). |
0 | -100 to 100 | 1 |
System
Applies to: any host; any insert.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 152 |
System Status (read-only) (advanced) Error flags, read-only. Bit 0 = host detection error. |
0 | 0 to 1 | 4 |
| 153 |
System LED Brightness Status LED brightness (%). |
100 | 0 to 100 | 1 |
| 154 |
System Options Bit 0 = invert the LED (LED on while the load is off). |
0 | 0 to 1 | 2 |
| 155 |
Host Change Operation What the insert does when it powers up in a different host. 0 = nothing; 1 = flash the LED if the host type changed; 2 = flash the LED if the host changed; 3 = reset if the host type changed; 4 = reset if the host changed. |
4 | 0 to 4 | 1 |
On/off switch
Applies to: On/off switch; any insert.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 168 |
3-Way Switch Options Bit 0 = 3-way wiring; bit 1 = invert on/off. |
0 | 0 to 3 | 2 |
Dimmer
Applies to: Dimmer, Multi-way dimmer; any insert.
| # | Parameter | Default | Range | Bytes |
|---|---|---|---|---|
| 192 |
FW 2.0 Dimmer Minimum Brightness (advanced) Lowest dimmer output level (%). |
42 | 20 to 80 | 1 |
| 193 |
Dimmer Maximum Brightness (advanced) Highest dimmer output level (%). |
100 | 80 to 100 | 1 |
| 194 |
Dimmer Default Brightness Level used when turned on without a level (%). |
80 | 0 to 100 | 1 |
Moving an insert to another host
When the insert powers up in a different host (with parameter 155 at its default of 4), it tells the hub it has been reset, leaves the network, then tries a SmartStart join with its new identity. Hubs without SmartStart, or that don't drop a node on reset, need a manual remove and add, and associations and scenes have to be set up again. The safe course:
- Remove the insert from your hub's network: hold the button 5 to 10 s (blue) with the hub in exclusion mode.
- Move the insert to the new host.
- Add it again, by SmartStart or with the button, then set up its associations and scenes.
Firmware
| Version | Date | Notes |
|---|---|---|
| FW 1.5 FW 1.6 | 2024-04 | first releases |
| FW 1.7 | 2024-04-30 | better join detection and initial reports; the air quality VOC value is sent with every air quality notification |
| FW 1.8 | 2024-11-29 | notifications, reports and association commands no longer lost under load; configuration storage reworked |
| FW 2.0 | 2026-11-16 | newer Z-Wave SDK (7.21), Long Range, fixes below. Current firmware. |
What 2.0 changes
- FW 2.0 Built on Z-Wave SDK 7.21, which fixes known issues in the older platform.
- FW 2.0 Z-Wave Long Range (US and Canada).
- FW 2.0 Settings 32, 64, 96, 128 and 192 are listed to hubs.
- FW 2.0 The temperature offset (96) works correctly in Fahrenheit.
- FW 2.0 Idle notifications name the event that cleared.
- FW 2.0 With a motion insert in a dimmer, the motion automation turns the light on.
Downloads
- Firmware 2.0: Download
- Firmware 1.8 (only needed to step up from 1.7 or older): swidget_secure_ota_1_8_0.gbl
Step-by-step instructions for Home Assistant: Updating a Swidget Z-Wave insert to firmware 2.0. Release notes: Z-Wave insert firmware: changes by version. An updated insert stays on standard mesh; to move it to Long Range, make a Long Range code, then remove it and add it again with that code.
Updating
- Over the air through a hub that supports Z-Wave firmware updates (for example Home Assistant with Z-Wave JS). The insert stays in the network with its settings and associations.
- With a hub that can't update Swidget inserts (SmartThings, for example), with a Z-Wave USB stick: see Updating Z-Wave Insert Firmware Using a Z-Wave USB Stick. That route removes the insert from your hub and adds it back, so its settings and associations have to be set up again.
- Over the air, updating from 1.7 to 1.8 or from 1.8 to 2.0 keeps the inclusion, associations, parameters and endpoints.
- Updates are one way: an insert updated to firmware 2.0 cannot go back to 1.x.
- On 1.7 or older, update to 1.8 first.
- Inserts accept only firmware files signed by Swidget.
Getting help
Email us at support@swidget.com or use the contact form at swidget.com.
Comments
0 comments
Please sign in to leave a comment.