What changed in each firmware release for Swidget Z-Wave 800-series inserts (ZW000UWA, ZW001UWA, ZW006UWA, ZW008UWA). One firmware serves all four models. Newest release first.
FW 2.0 Firmware 2.0 (2026-11-16)
Download firmware 2.0. How to install it: Updating a Swidget Z-Wave insert to firmware 2.0. Inserts on 1.7 or older must go to 1.8 first. Updates are one way: an insert on 2.0 can't go back to 1.x.
- Platform: firmware 2.0 is built on Silicon Labs Z-Wave SDK 7.21 (firmware 1.8 uses 7.18). The newer platform fixes known issues in the older one.
- Z-Wave Long Range (US and Canada): firmware 2.0 supports Z-Wave Long Range. Inserts sold with 1.x firmware need a Long Range version of their QR code, made at the Swidget Long Range QR code page. An insert updated from 1.8 stays on standard mesh until it is removed and added again with that code.
- Five more settings shown to hubs: firmware 1.8 had these settings but did not show them to the hub; firmware 2.0 lists them on the insert's configuration page.
- Fix, temperature offset in Fahrenheit: on firmware 1.8, setting a temperature offset with the insert reporting in °F shifted readings by about -17.8 °C. On firmware 2.0 the offset works in both units.
- Fix, clearer idle notifications: on firmware 2.0, when motion or an air-quality alert clears, the insert says which event ended. Firmware 1.8 always sent 00, so hubs had to guess which state to clear.
- Fix, motion turns on the dimmer: with a motion insert in a dimmer, the built-in motion automation now really turns the light on. On firmware 1.8 the hub was told the light was on while it stayed off.
| No. | Setting shown to hubs from firmware 2.0 | Shown for |
|---|---|---|
| 32 | Power 2 Renotification Delay: how often to repeat a high or low power alert for the bottom receptacle (seconds, 0 = off) | 15 A and 20 A outlets |
| 64 | Air Quality Level 1 Index: the air quality index at which air counts as level 1 (default 100) | Air Quality insert |
| 96 | Temperature Offset: calibration added to the reading, in tenths of a degree of the unit you've chosen | Temperature/Humidity/Motion and Air Quality inserts |
| 128 | Humidity High Entry Level: the humidity (%RH) at which the high-humidity state starts | Temperature/Humidity/Motion and Air Quality inserts |
| 192 | Dimmer Minimum Brightness: the lowest level the dimmer goes to (20 to 80 %, default 42) | Dimmers |
Everything else works as on firmware 1.8. Updated over the air through a hub such as Home Assistant, the insert stays in your network, along with its settings, associations and the automations you've built around it. The USB-stick route for hubs that can't update Swidget inserts removes the insert and adds it back, so its settings and associations have to be set up again.
FW 1.8 Firmware 1.8 (2024-11-29)
- Notifications, reports and association commands are no longer lost under load; configuration storage reworked.
- Download (only needed to step up from 1.7 or older): swidget_secure_ota_1_8_0.gbl.
FW 1.7 Firmware 1.7 (2024-04-30)
- Better join detection and initial reports; the air quality VOC value is sent with every air quality notification.
FW 1.5 Firmware 1.5 and 1.6 (2024-04)
- First releases.
Comments
0 comments
Please sign in to leave a comment.