For additional parameters and to learn more, please download our Swidget Z-Wave Universal Insert Configuration guide.
Air Quality Alert Level
Parameter: 67 (0x0043)
Description: Used to set the air quality level that will trigger Air Quality Alert State actions.
Range: 1 to 3
Units: Air quality level: 1 = "Slightly Polluted", 2 = "Moderately Polluted", 3 = "Extremely Polluted"
Default: 2 ("Moderately Polluted")
Air Quality Alert Delay
Parameter: 68 (0x0044)
Description: Delay after detection of a level change before acting on change of air quality state.
Range: 0 – 65535
Units: Seconds
Default: 0
Air Quality Alert Entry SET Value
Parameter: 72 (0x0048)
Description: BASIC SET value sent to associated nodes on entry into air quality alert state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 255 (turn on associated devices)
Air Quality Alert Exit SET Value
Parameter: 73 (0x0049)
Description: BASIC SET value sent to associated nodes on exit from air quality alert state.
Range: 0 – 99 or 255
Units: BASIC CC SET LEVEL
Default: 0 (turn off associated devices)