20/40/60 CONTROL SWITCH
The Swidget 20/40/60 Control Switch was designed for use with ventilation products including your ERV/HRV Boost Mode, bathroom fans, and much more. There are a variety of ways this can be done, resulting in some potentially confusing control which this article will help to clarify.
SWITCH CONTROLS:
Manual Control - Note: A Swidget Insert is not required for normal Switch operation.
Automatic Insert Control - With a Swidget Insert installed that can monitor Air Quality, Humidity, or Motion, and while that Insert is not paired to the Swidget app, the 20/40/60 Control Switch will automatically turn ON and OFF when any of the following conditions are met:
Air Quality: When indoor air quality declines to moderate, the switch will turn ON until air quality improves to good for 5 minutes, at which point the switch will turn OFF.
Humidity: When relative humidity rises 15% above the daily average, the switch will turn ON. It stays on while the humidity stays that high, and turns OFF once the humidity has been back below that level for 5 minutes.
Motion: When occupancy is sensed, the switch will turn ON until unoccupied for 5 minutes, at which point the switch will turn OFF.
NOTE: These automatic rules run only while the Insert is not paired to the Swidget app. Once it is paired (2.4 GHz Wi-Fi), they stop and the switch follows the Modes of Operation or automations you set in the app.
Other Control - Your ERV/HRV Boost Mode can be on for a variety of reasons even when your 20/40/60 Control Switch is OFF. Here are a few reasons why your ERV/HRV may be ON:
-
boost mode has been activated at another location that controls the ERV/HRV
-
there is an automatic schedule that runs boost mode for a pre-determined interval
Comments